Energy Performance Certificate

32, The Street, Bramford, IP8 4EB

EPC Report

Energy rating

Current: 24 F | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 14 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 Current: 14 87 Potential: 87
Field Value
LMK KEY 8002-4775-9729-6797-4713
ADDRESS1 32, The Street
ADDRESS2 Bramford
ADDRESS3
POSTCODE IP8 4EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-03-13
LOCAL AUTHORITY E07000203
CONSTITUENCY E14001156
COUNTY
LODGEMENT DATE 2019-03-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 14
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 1057
ENERGY CONSUMPTION POTENTIAL 82
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 181
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 37
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 1134
HEATING COST POTENTIAL 314
HOT WATER COST CURRENT 255
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 42
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, The Street, Bramford
LOCAL AUTHORITY LABEL Mid Suffolk
CONSTITUENCY LABEL Central Suffolk and North Ipswich
POSTTOWN IPSWICH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-03-13 14:17:50
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100091088273
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew