Energy Performance Certificate

24, Connaught Drive, Chapel St. Leonards, PE24 5YS

EPC Report

Energy rating

Current: 49 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 35 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 50 Potential: 50
Field Value
LMK KEY 8000-7441-9329-9227-8753
ADDRESS1 24, Connaught Drive
ADDRESS2 Chapel St. Leonards
ADDRESS3
POSTCODE PE24 5YS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-03-24
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001114
COUNTY
LODGEMENT DATE 2015-03-24
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 518
ENERGY CONSUMPTION POTENTIAL 346
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 88
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 910
HEATING COST POTENTIAL 763
HOT WATER COST CURRENT 166
HOT WATER COST POTENTIAL 143
TOTAL FLOOR AREA 73
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, Connaught Drive, Chapel St. Leonards
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Boston and Skegness
POSTTOWN SKEGNESS
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-03-24 14:23:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100030784514
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew