Energy Performance Certificate

69, Front Street, Lockington, YO25 9SH

EPC Report

Energy rating

Current: 42 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 36 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 69 Potential: 69
Field Value
LMK KEY 7998-5012-7277-3345-9954
ADDRESS1 69, Front Street
ADDRESS2 Lockington
ADDRESS3
POSTCODE YO25 9SH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-31
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001087
COUNTY
LODGEMENT DATE 2015-04-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 288
ENERGY CONSUMPTION POTENTIAL 111
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1429
HEATING COST POTENTIAL 840
HOT WATER COST CURRENT 339
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 127
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 30
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 23
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 23% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 69, Front Street, Lockington
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Beverley and Holderness
POSTTOWN DRIFFIELD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-04-01 07:46:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100050048784
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew