Energy Performance Certificate

Sitheil, Pennington Road, Southborough, TN4 0SS

EPC Report

Energy rating

Current: 116 A | Potential: 118 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 116 A Current: 116 A 118 A Potential: 118 A

Environmental impact (CO₂)

Current: 114 | Potential: 116
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 114 Current: 114 116 Potential: 116
Field Value
LMK KEY 7949-2432-4609-1277-1202
ADDRESS1 Sitheil
ADDRESS2 Pennington Road
ADDRESS3 Southborough
POSTCODE TN4 0SS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 116
POTENTIAL ENERGY EFFICIENCY 118
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-12-03
LOCAL AUTHORITY E07000116
CONSTITUENCY E14001555
COUNTY
LODGEMENT DATE 2021-12-09
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 114
ENVIRONMENT IMPACT POTENTIAL 116
ENERGY CONSUMPTION CURRENT -91
ENERGY CONSUMPTION POTENTIAL -103
CO2 EMISSIONS CURRENT -3.2
CO2 EMISS CURR PER FLOOR AREA -15.4
CO2 EMISSIONS POTENTIAL -3.6
LIGHTING COST CURRENT 114
LIGHTING COST POTENTIAL 114
HEATING COST CURRENT 423
HEATING COST POTENTIAL 424
HOT WATER COST CURRENT 422
HOT WATER COST POTENTIAL 264
TOTAL FLOOR AREA 208
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.14 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, Underfloor heating, pipes in screed above insulation, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Sitheil, Pennington Road, Southborough
LOCAL AUTHORITY LABEL Tunbridge Wells
CONSTITUENCY LABEL Tunbridge Wells
POSTTOWN TUNBRIDGE WELLS
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2021-12-09 09:53:06
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10090057017
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew