Energy Performance Certificate
Route 1, 5 High Street, Thurlby, PE10 0ED
Energy rating
Current: 33 F | Potential: 72 C
Environmental impact (CO₂)
Current: 31
| Potential: 66
| Field | Value |
|---|---|
| LMK KEY | 7908-7083-7234-3755-7940 |
| ADDRESS1 | Route 1 |
| ADDRESS2 | 5 High Street |
| ADDRESS3 | Thurlby |
| POSTCODE | PE10 0ED |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 33 |
| POTENTIAL ENERGY EFFICIENCY | 72 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2015-04-30 |
| LOCAL AUTHORITY | E07000141 |
| CONSTITUENCY | E14001458 |
| COUNTY | — |
| LODGEMENT DATE | 2015-05-03 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 31 |
| ENVIRONMENT IMPACT POTENTIAL | 66 |
| ENERGY CONSUMPTION CURRENT | 303 |
| ENERGY CONSUMPTION POTENTIAL | 119 |
| CO2 EMISSIONS CURRENT | 13 |
| CO2 EMISS CURR PER FLOOR AREA | 75 |
| CO2 EMISSIONS POTENTIAL | 5.5 |
| LIGHTING COST CURRENT | 136 |
| LIGHTING COST POTENTIAL | 79 |
| HEATING COST CURRENT | 2384 |
| HEATING COST POTENTIAL | 1190 |
| HOT WATER COST CURRENT | 253 |
| HOT WATER COST POTENTIAL | 106 |
| TOTAL FLOOR AREA | 176 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | More Than Typical |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 8 |
| NUMBER HEATED ROOMS | 8 |
| LOW ENERGY LIGHTING | 29 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, oil |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 29% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | oil (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.35 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Route 1, 5 High Street, Thurlby |
| LOCAL AUTHORITY LABEL | South Kesteven |
| CONSTITUENCY LABEL | Rutland and Stamford |
| POSTTOWN | BOURNE |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2015-05-03 12:03:54 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 17 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| UPRN | 100030902971 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 2 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |