Energy Performance Certificate

22 Maria Court, Hesper Road, CO2 8JP

EPC Report

Energy rating

Current: 82 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 74 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 77 Potential: 77
Field Value
LMK KEY 7902-3329-0300-0090-0292
ADDRESS1 22 Maria Court
ADDRESS2 Hesper Road
ADDRESS3
POSTCODE CO2 8JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-01-10
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001273
COUNTY
LODGEMENT DATE 2022-01-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 191
ENERGY CONSUMPTION POTENTIAL 164
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 193
HEATING COST POTENTIAL 152
HOT WATER COST CURRENT 192
HOT WATER COST POTENTIAL 162
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.02
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 Maria Court, Hesper Road
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Harwich and North Essex
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2022-01-12 20:30:26
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 303003781
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew