Energy Performance Certificate

58 Lea Road, UB2 5QA

EPC Report

Energy rating

Current: 77 C | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 79 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 92 Potential: 92
Field Value
LMK KEY 7890-3048-9207-2405-7200
ADDRESS1 58 Lea Road
ADDRESS2
ADDRESS3
POSTCODE UB2 5QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-03-31
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001209
COUNTY
LODGEMENT DATE 2025-04-08
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 116
ENERGY CONSUMPTION POTENTIAL 36
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 670
HEATING COST POTENTIAL 516
HOT WATER COST CURRENT 246
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 112
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58 Lea Road
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing Southall
POSTTOWN SOUTHALL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-04-08 16:32:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 12026085
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew