Energy Performance Certificate

13b Brookmead, Hildenborough, TN11 9DJ

EPC Report

Energy rating

Current: 51 E | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 49 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 61 Potential: 61
Field Value
LMK KEY 7890-1011-6268-8772-6204
ADDRESS1 13b Brookmead
ADDRESS2 Hildenborough
ADDRESS3
POSTCODE TN11 9DJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2022-08-31
LOCAL AUTHORITY E07000115
CONSTITUENCY E14001549
COUNTY
LODGEMENT DATE 2022-09-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 326
ENERGY CONSUMPTION POTENTIAL 241
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 1042
HEATING COST POTENTIAL 999
HOT WATER COST CURRENT 91
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 104
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13b Brookmead, Hildenborough
LOCAL AUTHORITY LABEL Tonbridge and Malling
CONSTITUENCY LABEL Tonbridge
POSTTOWN TONBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2022-09-01 08:43:03
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100061167860
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew