Energy Performance Certificate

31 Enfield Close, Houghton Regis, LU5 5PL

EPC Report

Energy rating

Current: 74 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 73 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 77 Potential: 77
Field Value
LMK KEY 7820-9069-0087-3003-1623
ADDRESS1 31 Enfield Close
ADDRESS2 Houghton Regis
ADDRESS3
POSTCODE LU5 5PL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2026-06-17
LOCAL AUTHORITY E06000056
CONSTITUENCY E14001206
COUNTY
LODGEMENT DATE 2026-06-18
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 159
ENERGY CONSUMPTION POTENTIAL 129
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 894
HEATING COST POTENTIAL 816
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 222
TOTAL FLOOR AREA 96
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31 Enfield Close, Houghton Regis
LOCAL AUTHORITY LABEL Central Bedfordshire
CONSTITUENCY LABEL Dunstable and Leighton Buzzard
POSTTOWN DUNSTABLE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2026-06-18 17:05:57
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100080093772
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew