Energy Performance Certificate

8b Lyndale Road, CV5 8AX

EPC Report

Energy rating

Current: 71 C | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
LMK KEY 7809-3058-1209-8736-6200
ADDRESS1 8b Lyndale Road
ADDRESS2
ADDRESS3
POSTCODE CV5 8AX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2026-01-30
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001181
COUNTY
LODGEMENT DATE 2026-02-02
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 89
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 212
ENERGY CONSUMPTION POTENTIAL 212
CO2 EMISSIONS CURRENT 0.6
CO2 EMISS CURR PER FLOOR AREA 19
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 27
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 558
HEATING COST POTENTIAL 558
HOT WATER COST CURRENT 346
HOT WATER COST POTENTIAL 346
TOTAL FLOOR AREA 33
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.74
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8b Lyndale Road
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry North West
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-02-02 10:06:58
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070674214
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000005
Address display
Nation ew