Energy Performance Certificate

5, Orchard Road, Sleights, YO22 5BY

EPC Report

Energy rating

Current: 42 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 37 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 67 Potential: 67
Field Value
LMK KEY 7808-0055-6204-9772-9974
ADDRESS1 5, Orchard Road
ADDRESS2 Sleights
ADDRESS3
POSTCODE YO22 5BY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-04-30
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001461
COUNTY
LODGEMENT DATE 2012-04-30
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 359
ENERGY CONSUMPTION POTENTIAL 172
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1638
HEATING COST POTENTIAL 952
HOT WATER COST CURRENT 110
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 144
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 20
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Orchard Road, Sleights
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Scarborough and Whitby
POSTTOWN WHITBY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-04-30 14:53:11
TENURE
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100050500544
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew