Energy Performance Certificate

15 Barnards Field, Thaxted, CM6 2LY

EPC Report

Energy rating

Current: 70 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 88 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 91 Potential: 91
Field Value
LMK KEY 7700-7592-0922-6591-3763
ADDRESS1 15 Barnards Field
ADDRESS2 Thaxted
ADDRESS3
POSTCODE CM6 2LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2026-03-11
LOCAL AUTHORITY E07000077
CONSTITUENCY E14001402
COUNTY
LODGEMENT DATE 2026-04-08
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 158
ENERGY CONSUMPTION POTENTIAL 133
CO2 EMISSIONS CURRENT 1.0
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 939
HEATING COST POTENTIAL 939
HOT WATER COST CURRENT 395
HOT WATER COST POTENTIAL 395
TOTAL FLOOR AREA 70
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.24
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 15 Barnards Field, Thaxted
LOCAL AUTHORITY LABEL Uttlesford
CONSTITUENCY LABEL North West Essex
POSTTOWN DUNMOW
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2026-04-08 12:33:01
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 200004265900
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew