Energy Performance Certificate

Flat 42, Marine Court, Centurion Way, RM19 1ZU

EPC Report

Energy rating

Current: 78 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 65 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 68 Potential: 68
Field Value
LMK KEY 7639-9120-1109-0255-0206
ADDRESS1 Flat 42
ADDRESS2 Marine Court
ADDRESS3 Centurion Way
POSTCODE RM19 1ZU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-10-05
LOCAL AUTHORITY E06000034
CONSTITUENCY E14001546
COUNTY
LODGEMENT DATE 2021-10-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 255
ENERGY CONSUMPTION POTENTIAL 234
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 234
HEATING COST POTENTIAL 208
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 174
TOTAL FLOOR AREA 53
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 42, Marine Court, Centurion Way
LOCAL AUTHORITY LABEL Thurrock
CONSTITUENCY LABEL Thurrock
POSTTOWN PURFLEET
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-10-05 10:24:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100090739280
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew