Energy Performance Certificate

Swallows Nest, Tredower, Newtown, TR12 6DR

EPC Report

Energy rating

Current: 84 B | Potential: 108 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 108 A Potential: 108 A

Environmental impact (CO₂)

Current: 97 | Potential: 103
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 Current: 97 103 Potential: 103
Field Value
LMK KEY 7635-4533-0500-0650-2292
ADDRESS1 Swallows Nest
ADDRESS2 Tredower
ADDRESS3 Newtown
POSTCODE TR12 6DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 108
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-07-10
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2025-07-10
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 97
ENVIRONMENT IMPACT POTENTIAL 103
ENERGY CONSUMPTION CURRENT 38
ENERGY CONSUMPTION POTENTIAL -22
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 3.6
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 569
HEATING COST POTENTIAL 592
HOT WATER COST CURRENT 208
HOT WATER COST POTENTIAL 225
TOTAL FLOOR AREA 78
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.17 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Ground source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Swallows Nest, Tredower, Newtown
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN HELSTON
CONSTRUCTION AGE BAND 2025
LODGEMENT DATETIME 2025-07-10 12:07:50
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 50
UPRN 10012967613
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew