Energy Performance Certificate

47 Kendal Avenue, N18 1NE

EPC Report

Energy rating

Current: 57 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 48 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 73 Potential: 73
Field Value
LMK KEY 7609-3025-7207-8227-8200
ADDRESS1 47 Kendal Avenue
ADDRESS2
ADDRESS3
POSTCODE N18 1NE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-03-30
LOCAL AUTHORITY E09000010
CONSTITUENCY E14001221
COUNTY
LODGEMENT DATE 2023-04-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 271
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 215
LIGHTING COST POTENTIAL 164
HEATING COST CURRENT 2182
HEATING COST POTENTIAL 1421
HOT WATER COST CURRENT 259
HOT WATER COST POTENTIAL 176
TOTAL FLOOR AREA 114
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 69
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 69% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47 Kendal Avenue
LOCAL AUTHORITY LABEL Enfield
CONSTITUENCY LABEL Edmonton and Winchmore Hill
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-04-12 21:52:20
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 207076580
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew