Energy Performance Certificate

13, Park Avenue, BB11 4RH

EPC Report

Energy rating

Current: 55 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 48 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 68 Potential: 68
Field Value
LMK KEY 7598-0959-7230-1454-1904
ADDRESS1 13, Park Avenue
ADDRESS2
ADDRESS3
POSTCODE BB11 4RH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-10-31
LOCAL AUTHORITY E07000117
CONSTITUENCY E14001142
COUNTY
LODGEMENT DATE 2014-10-31
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 249
ENERGY CONSUMPTION POTENTIAL 149
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 5.0
LIGHTING COST CURRENT 147
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 1574
HEATING COST POTENTIAL 1179
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 174
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.99
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13, Park Avenue
LOCAL AUTHORITY LABEL Burnley
CONSTITUENCY LABEL Burnley
POSTTOWN BURNLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-10-31 12:42:53
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10003758793
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew