Energy Performance Certificate

6 Oban Road, B92 8BT

EPC Report

Energy rating

Current: 54 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 50 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 66 Potential: 66
Field Value
LMK KEY 7536-6024-7600-0123-1206
ADDRESS1 6 Oban Road
ADDRESS2
ADDRESS3
POSTCODE B92 8BT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2026-04-07
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001479
COUNTY
LODGEMENT DATE 2026-04-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 285
ENERGY CONSUMPTION POTENTIAL 186
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 2036
HEATING COST POTENTIAL 1421
HOT WATER COST CURRENT 317
HOT WATER COST POTENTIAL 317
TOTAL FLOOR AREA 113
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 89
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Oban Road
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Solihull West and Shirley
POSTTOWN SOLIHULL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-04-10 06:08:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 29
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 100071004000
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000005
Address display
Nation ew