Energy Performance Certificate

77 Bridle Way, Barwick, BA22 9TN

EPC Report

Energy rating

Current: 82 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 43 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 50 Potential: 50
Field Value
LMK KEY 7534-4829-7409-0968-3206
ADDRESS1 77 Bridle Way
ADDRESS2 Barwick
ADDRESS3
POSTCODE BA22 9TN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-11-08
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001603
COUNTY
LODGEMENT DATE 2025-02-19
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 366
ENERGY CONSUMPTION POTENTIAL 298
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 1267
HEATING COST POTENTIAL 1209
HOT WATER COST CURRENT 254
HOT WATER COST POTENTIAL 141
TOTAL FLOOR AREA 61
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77 Bridle Way, Barwick
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Yeovil
POSTTOWN YEOVIL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-02-19 09:44:01
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 30022418
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew