Energy Performance Certificate

44 Station Drive, Wisbech St. Mary, PE13 4RX

EPC Report

Energy rating

Current: 93 A | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 A Current: 93 A 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 94 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 Current: 94 94 Potential: 94
Field Value
LMK KEY 7501-3919-2309-0167-9204
ADDRESS1 44 Station Drive
ADDRESS2 Wisbech St. Mary
ADDRESS3
POSTCODE PE13 4RX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 93
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-11-30
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2023-11-30
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 94
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 33
ENERGY CONSUMPTION POTENTIAL 33
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 6
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 527
HEATING COST POTENTIAL 527
HOT WATER COST CURRENT 285
HOT WATER COST POTENTIAL 285
TOTAL FLOOR AREA 63
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.72 W/m²K
FLOOR ENERGY EFF Very Poor
FLOOR ENV EFF Very Poor
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.16 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 44 Station Drive, Wisbech St. Mary
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN WISBECH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2023-11-30 17:18:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100090085374
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew