Energy Performance Certificate

18 ST. GEORGES CRESCENT, NE66 1AY

EPC Report

Energy rating

Current: 65 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 63 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 81 Potential: 81
Field Value
LMK KEY 7499-1011-1203-7959-0200
ADDRESS1 18 ST. GEORGES CRESCENT
ADDRESS2
ADDRESS3
POSTCODE NE66 1AY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-07-31
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001397
COUNTY
LODGEMENT DATE 2021-08-02
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 310
ENERGY CONSUMPTION POTENTIAL 171
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 541
HEATING COST POTENTIAL 502
HOT WATER COST CURRENT 85
HOT WATER COST POTENTIAL 60
TOTAL FLOOR AREA 59
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18 ST. GEORGES CRESCENT
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL North Northumberland
POSTTOWN ALNWICK
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-08-02 21:41:19
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100110571988
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000001
Address display
Nation ew