Energy Performance Certificate

81 Durrington Road, BH7 6PZ

EPC Report

Energy rating

Current: 57 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 47 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 68 Potential: 68
Field Value
LMK KEY 7420-0053-0757-1002-1583
ADDRESS1 81 Durrington Road
ADDRESS2
ADDRESS3
POSTCODE BH7 6PZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-05-09
LOCAL AUTHORITY E06000058
CONSTITUENCY E14001115
COUNTY
LODGEMENT DATE 2025-05-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 260
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 217
LIGHTING COST POTENTIAL 135
HEATING COST CURRENT 2028
HEATING COST POTENTIAL 1411
HOT WATER COST CURRENT 175
HOT WATER COST POTENTIAL 147
TOTAL FLOOR AREA 180
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 39
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 39% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 81 Durrington Road
LOCAL AUTHORITY LABEL Bournemouth, Christchurch and Poole
CONSTITUENCY LABEL Bournemouth East
POSTTOWN BOURNEMOUTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-05-10 10:05:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100040732778
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew