Energy Performance Certificate

2 ALANBROOKE CLOSE, HARTLEY WINTNEY, HOOK, RG27 8QY

EPC Report

Energy rating

Current: 59 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 50 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 66 Potential: 66
Field Value
LMK KEY 7403-1006-8201-1340-0200
ADDRESS1 2 ALANBROOKE CLOSE
ADDRESS2 HARTLEY WINTNEY
ADDRESS3 HOOK
POSTCODE RG27 8QY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-09-30
LOCAL AUTHORITY E07000089
CONSTITUENCY E14001392
COUNTY
LODGEMENT DATE 2020-10-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 236
ENERGY CONSUMPTION POTENTIAL 148
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 168
LIGHTING COST POTENTIAL 113
HEATING COST CURRENT 1503
HEATING COST POTENTIAL 1185
HOT WATER COST CURRENT 138
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 199
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 52
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 52% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 ALANBROOKE CLOSE, HARTLEY WINTNEY, HOOK
LOCAL AUTHORITY LABEL Hart
CONSTITUENCY LABEL North East Hampshire
POSTTOWN HOOK
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-10-01 15:29:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100060418373
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew