Energy Performance Certificate

52, Reed Pool Close, Countesthorpe, LE8 5RE

EPC Report

Energy rating

Current: 33 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 31 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 64 Potential: 64
Field Value
LMK KEY 7398-1087-7235-2934-8930
ADDRESS1 52, Reed Pool Close
ADDRESS2 Countesthorpe
ADDRESS3
POSTCODE LE8 5RE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-05-31
LOCAL AUTHORITY E07000129
CONSTITUENCY E14001488
COUNTY
LODGEMENT DATE 2014-05-31
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 441
ENERGY CONSUMPTION POTENTIAL 190
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 85
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1402
HEATING COST POTENTIAL 816
HOT WATER COST CURRENT 345
HOT WATER COST POTENTIAL 190
TOTAL FLOOR AREA 103
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Reed Pool Close, Countesthorpe
LOCAL AUTHORITY LABEL Blaby
CONSTITUENCY LABEL South Leicestershire
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-05-31 10:37:19
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100030400001
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew