Energy Performance Certificate

4 Bertrand Road, BL1 4RS

EPC Report

Energy rating

Current: 41 E | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 26 | Potential: 46
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 46 Potential: 46
Field Value
LMK KEY 7318-0072-5002-0802-1092
ADDRESS1 4 Bertrand Road
ADDRESS2
ADDRESS3
POSTCODE BL1 4RS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-12-07
LOCAL AUTHORITY E08000001
CONSTITUENCY E14001110
COUNTY
LODGEMENT DATE 2023-01-07
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 46
ENERGY CONSUMPTION CURRENT 526
ENERGY CONSUMPTION POTENTIAL 332
CO2 EMISSIONS CURRENT 15.3
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 9.6
LIGHTING COST CURRENT 238
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 3234
HEATING COST POTENTIAL 2146
HOT WATER COST CURRENT 329
HOT WATER COST POTENTIAL 160
TOTAL FLOOR AREA 172
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.81
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Bertrand Road
LOCAL AUTHORITY LABEL Bolton
CONSTITUENCY LABEL Bolton North East
POSTTOWN BOLTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-02-17 21:03:48
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100010850708
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000002
Address display
Nation ew