Energy Performance Certificate

14, Brookview, Coldwaltham, RH20 1LU

EPC Report

Energy rating

Current: 55 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 43 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 78 Potential: 78
Field Value
LMK KEY 7308-2017-7263-1927-1920
ADDRESS1 14, Brookview
ADDRESS2 Coldwaltham
ADDRESS3
POSTCODE RH20 1LU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-07-30
LOCAL AUTHORITY E07000227
CONSTITUENCY E14001067
COUNTY
LODGEMENT DATE 2013-08-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 251
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 918
HEATING COST POTENTIAL 470
HOT WATER COST CURRENT 218
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Brookview, Coldwaltham
LOCAL AUTHORITY LABEL Horsham
CONSTITUENCY LABEL Arundel and South Downs
POSTTOWN PULBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-08-04 19:43:39
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100061827260
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew