Energy Performance Certificate

Severalls, Hatherop, GL7 3NA

EPC Report

Energy rating

Current: 34 F | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 29 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 49 Potential: 49
Field Value
LMK KEY 7300-7909-1722-9378-0673
ADDRESS1 Severalls
ADDRESS2 Hatherop
ADDRESS3
POSTCODE GL7 3NA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-06-30
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001386
COUNTY
LODGEMENT DATE 2023-07-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 257
ENERGY CONSUMPTION POTENTIAL 148
CO2 EMISSIONS CURRENT 48
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 29
LIGHTING COST CURRENT 890
LIGHTING COST POTENTIAL 474
HEATING COST CURRENT 14915
HEATING COST POTENTIAL 9966
HOT WATER COST CURRENT 208
HOT WATER COST POTENTIAL 208
TOTAL FLOOR AREA 728
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 37
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 15
NUMBER HEATED ROOMS 15
LOW ENERGY LIGHTING 9
NUMBER OPEN FIREPLACES 5
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil, Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 9% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS Severalls, Hatherop
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL North Cotswolds
POSTTOWN CIRENCESTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-07-01 13:12:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 75
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10013397987
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew