Energy Performance Certificate

14 St. Marys Road, DN1 2NP

EPC Report

Energy rating

Current: 47 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 50 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 77 Potential: 77
Field Value
LMK KEY 7295-3013-4209-0312-7204
ADDRESS1 14 St. Marys Road
ADDRESS2
ADDRESS3
POSTCODE DN1 2NP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-01-31
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001198
COUNTY
LODGEMENT DATE 2022-05-05
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 262
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 7.9
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 141
LIGHTING COST POTENTIAL 141
HEATING COST CURRENT 2250
HEATING COST POTENTIAL 1170
HOT WATER COST CURRENT 342
HOT WATER COST POTENTIAL 237
TOTAL FLOOR AREA 171
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 St. Marys Road
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster Central
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-05-05 13:05:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100050776883
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000003
Address display
Nation ew