Energy Performance Certificate

27 Persian Close, DE24 1AS

EPC Report

Energy rating

Current: 80 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 78 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 85 Potential: 85
Field Value
LMK KEY 7237-1921-8200-0826-9206
ADDRESS1 27 Persian Close
ADDRESS2
ADDRESS3
POSTCODE DE24 1AS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-09-06
LOCAL AUTHORITY E06000015
CONSTITUENCY E14001194
COUNTY
LODGEMENT DATE 2023-09-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 113
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 214
LIGHTING COST POTENTIAL 214
HEATING COST CURRENT 1174
HEATING COST POTENTIAL 1183
HOT WATER COST CURRENT 302
HOT WATER COST POTENTIAL 174
TOTAL FLOOR AREA 158
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 95
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 95% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27 Persian Close
LOCAL AUTHORITY LABEL Derby
CONSTITUENCY LABEL Derby South
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2023-09-06 21:41:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 10010684488
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000004
Address display
Nation ew