Energy Performance Certificate

1 William Road, PE13 2AA

EPC Report

Energy rating

Current: 52 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 46 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 68 Potential: 68
Field Value
LMK KEY 7236-8826-6600-0765-3222
ADDRESS1 1 William Road
ADDRESS2
ADDRESS3
POSTCODE PE13 2AA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2026-06-25
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2026-06-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 325
ENERGY CONSUMPTION POTENTIAL 177
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 1812
HEATING COST POTENTIAL 1028
HOT WATER COST CURRENT 188
HOT WATER COST POTENTIAL 188
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 63
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 William Road
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN WISBECH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-06-25 18:21:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100090086732
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew