Energy Performance Certificate
HIGHBURY, APPLETON ROAD, LONGWORTH, OX13 5EF
Energy rating
Current: 64 D | Potential: 74 C
Environmental impact (CO₂)
Current: 55
| Potential: 67
| Field | Value |
|---|---|
| LMK KEY | 7220-9161-0320-4101-1923 |
| ADDRESS1 | HIGHBURY |
| ADDRESS2 | APPLETON ROAD |
| ADDRESS3 | LONGWORTH |
| POSTCODE | OX13 5EF |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 64 |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2021-06-14 |
| LOCAL AUTHORITY | E07000180 |
| CONSTITUENCY | E14001591 |
| COUNTY | — |
| LODGEMENT DATE | 2021-07-30 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 55 |
| ENVIRONMENT IMPACT POTENTIAL | 67 |
| ENERGY CONSUMPTION CURRENT | 138 |
| ENERGY CONSUMPTION POTENTIAL | 93 |
| CO2 EMISSIONS CURRENT | 8.3 |
| CO2 EMISS CURR PER FLOOR AREA | 36 |
| CO2 EMISSIONS POTENTIAL | 6.0 |
| LIGHTING COST CURRENT | 147 |
| LIGHTING COST POTENTIAL | 147 |
| HEATING COST CURRENT | 1054 |
| HEATING COST POTENTIAL | 943 |
| HOT WATER COST CURRENT | 173 |
| HOT WATER COST POTENTIAL | 95 |
| TOTAL FLOOR AREA | 229 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 3 |
| NUMBER HABITABLE ROOMS | 7 |
| NUMBER HEATED ROOMS | 7 |
| LOW ENERGY LIGHTING | 80 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated at rafters |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, oil |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in 80% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | oil (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.44 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | HIGHBURY, APPLETON ROAD, LONGWORTH |
| LOCAL AUTHORITY LABEL | Vale of White Horse |
| CONSTITUENCY LABEL | Witney |
| POSTTOWN | ABINGDON |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2021-07-30 17:41:38 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 25 |
| LOW ENERGY FIXED LIGHT COUNT | 20 |
| UPRN | 100121311702 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2021.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |