Energy Performance Certificate

6 Morland Road, Marcham, OX13 6PY

EPC Report

Energy rating

Current: 22 F | Potential: 41 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 41 E Potential: 41 E

Environmental impact (CO₂)

Current: 33 | Potential: 48
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 48 Potential: 48
Field Value
LMK KEY 7220-7050-0964-0107-1573
ADDRESS1 6 Morland Road
ADDRESS2 Marcham
ADDRESS3
POSTCODE OX13 6PY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 41
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-05-30
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2025-06-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 48
ENERGY CONSUMPTION CURRENT 463
ENERGY CONSUMPTION POTENTIAL 310
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 78
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 96
HEATING COST CURRENT 2924
HEATING COST POTENTIAL 2445
HOT WATER COST CURRENT 503
HOT WATER COST POTENTIAL 269
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Morland Road, Marcham
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN ABINGDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2025-06-01 11:44:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100120907747
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew