Energy Performance Certificate

6, Pant Celydd, Margam, SA13 2DJ

EPC Report

Energy rating

Current: 93 A | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 A Current: 93 A 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 95 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 95 Current: 95 95 Potential: 95
Field Value
LMK KEY 7205-3906-1309-6237-9204
ADDRESS1 6
ADDRESS2 Pant Celydd
ADDRESS3 Margam
POSTCODE SA13 2DJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 93
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2023-11-30
LOCAL AUTHORITY W06000012
CONSTITUENCY W07000081
COUNTY
LODGEMENT DATE 2023-11-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 95
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 21
ENERGY CONSUMPTION POTENTIAL 21
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 4
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 113
HEATING COST CURRENT 330
HEATING COST POTENTIAL 330
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 174
TOTAL FLOOR AREA 62
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 6, Pant Celydd, Margam
LOCAL AUTHORITY LABEL Neath Port Talbot
CONSTITUENCY LABEL Aberafan Maesteg
POSTTOWN PORT TALBOT
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2023-11-30 10:00:03
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10094265129
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew