Energy Performance Certificate

Old Court, Lissington, LN3 5AE

EPC Report

Energy rating

Current: 17 G | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 16 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 47 Potential: 47
Field Value
LMK KEY 7196-3034-2209-7144-3204
ADDRESS1 Old Court
ADDRESS2 Lissington
ADDRESS3
POSTCODE LN3 5AE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-01-31
LOCAL AUTHORITY E07000142
CONSTITUENCY E14001243
COUNTY
LODGEMENT DATE 2024-02-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 406
ENERGY CONSUMPTION POTENTIAL 183
CO2 EMISSIONS CURRENT 21
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 9.8
LIGHTING COST CURRENT 345
LIGHTING COST POTENTIAL 189
HEATING COST CURRENT 4675
HEATING COST POTENTIAL 2526
HOT WATER COST CURRENT 326
HOT WATER COST POTENTIAL 129
TOTAL FLOOR AREA 197
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 66
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 16
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil, Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 16% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.03
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Old Court, Lissington
LOCAL AUTHORITY LABEL West Lindsey
CONSTITUENCY LABEL Gainsborough
POSTTOWN LINCOLN
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-02-04 15:16:01
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10034699981
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000004
Address display
Nation ew