Energy Performance Certificate

69 Kings House, Queens Gardens, BN3 2QU

EPC Report

Energy rating

Current: 60 D | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 64 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 64 Potential: 64
Field Value
LMK KEY 7100-7973-0732-1028-3493
ADDRESS1 69 Kings House
ADDRESS2 Queens Gardens
ADDRESS3
POSTCODE BN3 2QU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-04-23
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001296
COUNTY
LODGEMENT DATE 2021-04-23
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 170
ENERGY CONSUMPTION POTENTIAL 170
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 6.6
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 119
HEATING COST CURRENT 1895
HEATING COST POTENTIAL 1895
HOT WATER COST CURRENT 377
HOT WATER COST POTENTIAL 377
TOTAL FLOOR AREA 228
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.38 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.16 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 69 Kings House, Queens Gardens
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Hove and Portslade
POSTTOWN Hove
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2021-04-23 16:36:18
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 22267734
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew