Energy Performance Certificate

22 BURLINGTON CLOSE, KIRKBY-IN-FURNESS, LA17 7UG

EPC Report

Energy rating

Current: 46 E | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 33 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 73 Potential: 73
Field Value
LMK KEY 7090-2810-0522-8005-3003
ADDRESS1 22 BURLINGTON CLOSE
ADDRESS2 KIRKBY-IN-FURNESS
ADDRESS3
POSTCODE LA17 7UG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2020-10-09
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001076
COUNTY
LODGEMENT DATE 2020-10-21
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 658
ENERGY CONSUMPTION POTENTIAL 224
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 111
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 809
HEATING COST POTENTIAL 424
HOT WATER COST CURRENT 407
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 49
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 BURLINGTON CLOSE, KIRKBY-IN-FURNESS
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Barrow and Furness
POSTTOWN KIRKBY-IN-FURNESS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-10-21 10:48:45
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100110346118
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew