Energy Performance Certificate

73 George Street, PO33 2JF

EPC Report

Energy rating

Current: 70 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 69 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 73 Potential: 73
Field Value
LMK KEY 7035-5129-0509-0058-2292
ADDRESS1 73 George Street
ADDRESS2
ADDRESS3
POSTCODE PO33 2JF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-11-18
LOCAL AUTHORITY E06000046
CONSTITUENCY E14001303
COUNTY
LODGEMENT DATE 2025-11-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 142
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 5.4
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 102
HEATING COST CURRENT 2185
HEATING COST POTENTIAL 1973
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 222
TOTAL FLOOR AREA 263
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 31
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 73 George Street
LOCAL AUTHORITY LABEL Isle of Wight
CONSTITUENCY LABEL Isle of Wight East
POSTTOWN RYDE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2025-11-19 09:10:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 50
UPRN 100060762464
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew