Energy Performance Certificate

FLAT 6 HARRY EDWARDS HOUSE, WINSTON AVENUE, CV2 1DN

EPC Report

Energy rating

Current: 64 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 54 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 59 Potential: 59
Field Value
LMK KEY 7005-3000-5201-1510-3200
ADDRESS1 FLAT 6 HARRY EDWARDS HOUSE
ADDRESS2 WINSTON AVENUE
ADDRESS3
POSTCODE CV2 1DN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2020-09-30
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001180
COUNTY
LODGEMENT DATE 2021-07-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 394
ENERGY CONSUMPTION POTENTIAL 357
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 401
HEATING COST POTENTIAL 328
HOT WATER COST CURRENT 251
HOT WATER COST POTENTIAL 157
TOTAL FLOOR AREA 42
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3
FLOOR HEIGHT 3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS FLAT 6 HARRY EDWARDS HOUSE, WINSTON AVENUE
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry East
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-07-15 15:48:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100071497674
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew