Energy Performance Certificate

148 Malvern Crescent, LE65 2HW

EPC Report

Energy rating

Current: 67 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 55 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 89 Potential: 89
Field Value
LMK KEY 7002-3015-5207-5692-0200
ADDRESS1 148 Malvern Crescent
ADDRESS2
ADDRESS3
POSTCODE LE65 2HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-03-30
LOCAL AUTHORITY E07000134
CONSTITUENCY E14001404
COUNTY
LODGEMENT DATE 2022-04-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 821
HEATING COST POTENTIAL 345
HOT WATER COST CURRENT 281
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 91
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak, plus solar
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 148 Malvern Crescent
LOCAL AUTHORITY LABEL North West Leicestershire
CONSTITUENCY LABEL North West Leicestershire
POSTTOWN ASHBY-DE-LA-ZOUCH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2022-04-04 10:28:23
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100030552750
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew