Energy Performance Certificate

BELLFLOWER BARN, CHAPEL FARM BARNS, THE GREEN, PE8 5LD

EPC Report

Energy rating

Current: 72 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 67 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 75 Potential: 75
Field Value
LMK KEY 7000-0175-0622-6023-3103
ADDRESS1 BELLFLOWER BARN
ADDRESS2 CHAPEL FARM BARNS
ADDRESS3 THE GREEN
POSTCODE PE8 5LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-09-23
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001179
COUNTY
LODGEMENT DATE 2020-09-25
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 118
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 112
HEATING COST CURRENT 623
HEATING COST POTENTIAL 627
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 163
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS BELLFLOWER BARN, CHAPEL FARM BARNS, THE GREEN
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Corby and East Northamptonshire
POSTTOWN ASHTON
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2020-09-25 08:11:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 10090613826
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000004
Address display
Nation ew