Energy Performance Certificate

39 THORNHURST, CHURCHILL AVENUE, HERNE BAY, CT6 6SQ

EPC Report

Energy rating

Current: 77 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 80 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 81 Potential: 81
Field Value
LMK KEY 6839-6029-5000-0867-3296
ADDRESS1 39 THORNHURST
ADDRESS2 CHURCHILL AVENUE
ADDRESS3 HERNE BAY
POSTCODE CT6 6SQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2021-01-13
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2021-01-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 187
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 1.0
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 155
HEATING COST POTENTIAL 157
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 31
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39 THORNHURST, CHURCHILL AVENUE, HERNE BAY
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN HERNE BAY
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-01-14 09:10:12
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100062053600
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew