Energy Performance Certificate

4 Maplewood, 14B Maple Road, RH1 5HE

EPC Report

Energy rating

Current: 83 B | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 83 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 92 Potential: 92
Field Value
LMK KEY 6800-4375-0232-8091-3843
ADDRESS1 4 Maplewood
ADDRESS2 14B Maple Road
ADDRESS3
POSTCODE RH1 5HE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-08-13
LOCAL AUTHORITY E07000211
CONSTITUENCY E14001442
COUNTY
LODGEMENT DATE 2024-08-13
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 94
ENERGY CONSUMPTION POTENTIAL 37
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 136
HEATING COST CURRENT 517
HEATING COST POTENTIAL 517
HOT WATER COST CURRENT 200
HOT WATER COST POTENTIAL 132
TOTAL FLOOR AREA 122
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.15 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.15 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 4 Maplewood, 14B Maple Road
LOCAL AUTHORITY LABEL Reigate and Banstead
CONSTITUENCY LABEL Reigate
POSTTOWN REDHILL
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2024-08-13 04:22:25
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 60
LOW ENERGY FIXED LIGHT COUNT 60
UPRN 68177987
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew