Energy Performance Certificate

5 NEWMAN CLOSE, WESTERLEIGH, BS37 8QT

EPC Report

Energy rating

Current: 63 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 49 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 68 Potential: 68
Field Value
LMK KEY 6739-0226-3000-0108-7292
ADDRESS1 5 NEWMAN CLOSE
ADDRESS2 WESTERLEIGH
ADDRESS3
POSTCODE BS37 8QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2021-06-18
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001545
COUNTY
LODGEMENT DATE 2021-06-18
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 448
ENERGY CONSUMPTION POTENTIAL 264
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 642
HEATING COST POTENTIAL 471
HOT WATER COST CURRENT 283
HOT WATER COST POTENTIAL 136
TOTAL FLOOR AREA 41
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters, Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY 30
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 NEWMAN CLOSE, WESTERLEIGH
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL Thornbury and Yate
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-06-18 17:30:02
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 553960
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew