Energy Performance Certificate

35 Durlston Close, Amington, B77 3QG

EPC Report

Energy rating

Current: 76 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 74 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 76 Potential: 76
Field Value
LMK KEY 6705-8496-0302-0097-9502
ADDRESS1 35 Durlston Close
ADDRESS2 Amington
ADDRESS3
POSTCODE B77 3QG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2026-03-13
LOCAL AUTHORITY E07000199
CONSTITUENCY E14001538
COUNTY
LODGEMENT DATE 2026-03-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 127
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1179
HEATING COST POTENTIAL 1179
HOT WATER COST CURRENT 275
HOT WATER COST POTENTIAL 275
TOTAL FLOOR AREA 177
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35 Durlston Close, Amington
LOCAL AUTHORITY LABEL Tamworth
CONSTITUENCY LABEL Tamworth
POSTTOWN TAMWORTH
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2026-03-15 19:12:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 394008655
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000005
Address display
Nation ew