Energy Performance Certificate

27 The Crescent, Maghull, L31 7BL

EPC Report

Energy rating

Current: 48 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 83 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 88 Potential: 88
Field Value
LMK KEY 6404-4185-9002-0099-4596
ADDRESS1 27 The Crescent
ADDRESS2 Maghull
ADDRESS3
POSTCODE L31 7BL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-11-14
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001463
COUNTY
LODGEMENT DATE 2025-11-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 182
ENERGY CONSUMPTION POTENTIAL 145
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 2169
HEATING COST POTENTIAL 1328
HOT WATER COST CURRENT 414
HOT WATER COST POTENTIAL 438
TOTAL FLOOR AREA 92
ENERGY TARIFF off-peak 10 hour
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27 The Crescent, Maghull
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Sefton Central
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-11-14 14:41:54
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 41094654
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew