Energy Performance Certificate

82 Highlander Drive, Donnington, TF2 8JZ

EPC Report

Energy rating

Current: 75 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 60 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 60 Potential: 60
Field Value
LMK KEY 6337-3725-5100-0719-6296
ADDRESS1 82 Highlander Drive
ADDRESS2 Donnington
ADDRESS3
POSTCODE TF2 8JZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Maisonette
BUILT FORM Detached
INSPECTION DATE 2023-05-11
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001543
COUNTY
LODGEMENT DATE 2023-05-11
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 294
ENERGY CONSUMPTION POTENTIAL 294
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 134
LIGHTING COST POTENTIAL 134
HEATING COST CURRENT 656
HEATING COST POTENTIAL 656
HOT WATER COST CURRENT 304
HOT WATER COST POTENTIAL 304
TOTAL FLOOR AREA 67
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 82 Highlander Drive, Donnington
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL The Wrekin
POSTTOWN TELFORD
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2023-05-11 15:57:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 452097159
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000005
Address display
Nation ew