Energy Performance Certificate

28, Nicholson Place, Rottingdean, BN2 7FZ

EPC Report

Energy rating

Current: 76 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 80 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 87 Potential: 87
Field Value
LMK KEY 6300-0366-0432-2007-3523
ADDRESS1 28
ADDRESS2 Nicholson Place
ADDRESS3 Rottingdean
POSTCODE BN2 7FZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-05-06
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001129
COUNTY
LODGEMENT DATE 2022-05-06
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 104
ENERGY CONSUMPTION POTENTIAL 59
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 104
HEATING COST CURRENT 736
HEATING COST POTENTIAL 736
HOT WATER COST CURRENT 85
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 136
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.23 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, electric, Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 28, Nicholson Place, Rottingdean
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Kemptown and Peacehaven
POSTTOWN Brighton
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2022-05-06 15:17:16
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 22275279
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew