Energy Performance Certificate

Flat 7, 5 Albert Road, BN1 3RL

EPC Report

Energy rating

Current: 45 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 47 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 71 Potential: 71
Field Value
LMK KEY 6220-9271-0174-0003-0233
ADDRESS1 Flat 7
ADDRESS2 5 Albert Road
ADDRESS3
POSTCODE BN1 3RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-03-10
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001130
COUNTY
LODGEMENT DATE 2022-03-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 629
ENERGY CONSUMPTION POTENTIAL 334
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 25
LIGHTING COST POTENTIAL 29
HEATING COST CURRENT 672
HEATING COST POTENTIAL 186
HOT WATER COST CURRENT 155
HOT WATER COST POTENTIAL 179
TOTAL FLOOR AREA 26
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 40
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.2
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 7, 5 Albert Road
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Pavilion
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-03-10 15:14:00
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 3
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 22113643
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew