Energy Performance Certificate

34 Fleming Walk, Church Village, CF38 1GF

EPC Report

Energy rating

Current: 80 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 94 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 Current: 94 95 Potential: 95
Field Value
LMK KEY 6104-0146-0002-1395-0502
ADDRESS1 34 Fleming Walk
ADDRESS2 Church Village
ADDRESS3
POSTCODE CF38 1GF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2026-05-19
LOCAL AUTHORITY W06000016
CONSTITUENCY W07000106
COUNTY
LODGEMENT DATE 2026-05-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 94
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 81
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 0.5
CO2 EMISS CURR PER FLOOR AREA 8
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 350
HEATING COST POTENTIAL 199
HOT WATER COST CURRENT 397
HOT WATER COST POTENTIAL 393
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34 Fleming Walk, Church Village
LOCAL AUTHORITY LABEL Rhondda Cynon Taf
CONSTITUENCY LABEL Pontypridd
POSTTOWN PONTYPRIDD
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2026-05-19 11:30:13
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10001300654
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew