Energy Performance Certificate

6 Sidgate, Newbrough, NE47 5AF

EPC Report

Energy rating

Current: 67 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 70 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 87 Potential: 87
Field Value
LMK KEY 6100-3167-0522-5191-3343
ADDRESS1 6 Sidgate
ADDRESS2 Newbrough
ADDRESS3
POSTCODE NE47 5AF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-07-16
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001285
COUNTY
LODGEMENT DATE 2024-07-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 243
ENERGY CONSUMPTION POTENTIAL 121
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 104
HEATING COST CURRENT 1094
HEATING COST POTENTIAL 880
HOT WATER COST CURRENT 440
HOT WATER COST POTENTIAL 303
TOTAL FLOOR AREA 72
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Sidgate, Newbrough
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL Hexham
POSTTOWN HEXHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-07-16 13:08:05
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100110640665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000001
Address display
Nation ew