Energy Performance Certificate

1, King Edward Avenue, LE13 1FW

EPC Report

Energy rating

Current: 62 D | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 33 | Potential: 33
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 33 Potential: 33
Field Value
LMK KEY 6100-0466-0832-2095-3293
ADDRESS1 1
ADDRESS2 King Edward Avenue
ADDRESS3
POSTCODE LE13 1FW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-02-16
LOCAL AUTHORITY E07000133
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2021-02-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 33
ENERGY CONSUMPTION CURRENT 539
ENERGY CONSUMPTION POTENTIAL 539
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 991
HEATING COST POTENTIAL 991
HOT WATER COST CURRENT 171
HOT WATER COST POTENTIAL 171
TOTAL FLOOR AREA 78
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.50 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.26
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1, King Edward Avenue
LOCAL AUTHORITY LABEL Melton
CONSTITUENCY LABEL Melton and Syston
POSTTOWN Melton Mowbray
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2021-02-16 15:27:10
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10095606140
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000004
Address display
Nation ew